


SPECIALIST COMMERCIAL KITCHEN FIRE PROTECTION
Amerex Kitchen Fire Suppression Systems & STRIKE
UL 300 Certified Fire Protection for High-Risk Cooking Environments
Protect your cooking operation with Amerex KP and STRIKE, supported by specialist design, installation, maintenance and ongoing fire safety management. Equipro helps you compare the complete specification: coverage, cylinders, detection, controls and the work needed to keep protection ready throughout its life.

Why Commercial Kitchens Require Engineered Fire Protection
High-energy Class F fires escalate rapidly in modern cooking appliances
Grease-laden ductwork presents hidden fire propagation risk
Unattended cooking equipment increases ignition probability
Fire events often lead to business interruption and insurance exposure
Commercial kitchens require an engineered combination of appliance, canopy and duct coverage, suitable detection and release, and a maintained system that matches the approved design.
Article 17: a set release is not proof of discharge readiness
A necessary R-102 system left unable to discharge because its essential cartridge is missing or insufficiently charged is not in the efficient working order required by Article 17.
In the conventional mechanical ANSUL R-102 arrangement reviewed, the release mechanism can be cocked without a gas cartridge installed. Its cocked indication does not establish cartridge presence or adequate charge. An apparently set release can therefore conceal an affected discharge arrangement that cannot operate as intended. A service sticker or successful release-mechanism test alone does not verify subsequent cartridge installation and charge. The manufacturer’s separate cartridge checks, controlled reinstatement and appropriate ongoing checking arrangements matter.
Amerex: pressure conditions you can check
Amerex KP has visible pressure gauges on its stored-pressure agent cylinders. The reviewed MRM/PRM arrangements also provide a gauge on the nitrogen actuation cylinder. Those gauges make these essential pressure conditions directly checkable and can help identify pressure loss between service visits.
This is a comparison of the conventional mechanical R-102 arrangement reviewed. It does not mean every R-102 installation is non-compliant. Article 17 does not prescribe a pressure gauge or continuous cartridge supervision. Gauges do not establish agent quantity, clear pipework or complete system operability, and STRIKE circuit supervision is not universal pressure monitoring.
Technical basis: ANSUL R-102 manual 418087-12, September 2014, sections 7-6 and 8-5; Amerex manual 20150, section 6-2 item 9. Current approved instructions govern each installation.
Foodservice expertise and fire safety competence are different responsibilities
Foodservice design consultants, foodservice ventilation companies and kitchen-system installation companies should not be assumed to be trained or competent in the Fire Safety Order simply because of their professional role. Expertise in kitchen layouts, extraction or installation does not, by itself, demonstrate competence to assess fire-safety duties or advise a client on compliance.
Those making or advising on fire-protection decisions need appropriate fire-safety knowledge for the work they undertake. Where that knowledge is absent, relevant education, training and competent specialist support are needed. Manufacturer system training and understanding the Fire Safety Order are distinct competencies.
The Article 17 verification gap is a practical example. Designers, specifiers, installers and maintainers need to understand what a set indication actually confirms, how the discharge gas supply is verified, what must be checked after maintenance, and how faults or uncertain readiness are escalated.
Recognise the difference between a cocked release and a discharge-ready system
Understand cartridge checks and correct reinstatement
Specify appropriate ongoing checks, records and impairment arrangements
Coordinate suppression with the fire risk assessment, training and wider premises precautions
Equipro works with consultants, ventilation contractors and kitchen installers to strengthen specifications and discuss role-appropriate technical education and training.
1) Mechanical Fusible Link System
Traditional mechanical activation method
Fusible-link and cable arrangement
Requires thermal link failure to activate
Amerex provides multiple detection architectures. MRM uses fusible links and cable; PRM uses pneumatic linear tubing as a maintained consumable; STRIKE uses supervised detection, manual activation and actuation circuits.
Amerex KPâ„¢ System Architecture
Amerex systems are available in three distinct detection and activation configurations, allowing system design to match risk profile and operational environment.
2) Pneumatic Detection System (Linear Tube)
Heat-sensitive pneumatic linear tubing
Distributed detection across protected areas
Maintained consumable requiring appropriate inspection and replacement
3) STRIKEâ„¢ Electric Detection System
Supervised detection, manual activation and actuation circuits
Fault indication and event recording
Primary and secondary battery power for the core panel
Auxiliaries may need power depending on the approved configuration

What we check in your kitchen protection specification
Automatic and manual fire suppression activation
Wet chemical agent delivery to high-risk areas
Approved appliance, canopy and duct coverage
Suitable detection and manual release arrangement
Permitted piping and nozzle arrangement
Agreed fuel and electrical shutdown, alarm and ventilation interfaces
Tested standards within approved scope
UL 300 and manufacturer-reported EN 17446 certification should be understood only within the applicable approved scope and installation instructions. Certification does not by itself establish compliance for every project.
UL 300 — Primary Performance Standard
- Validates suppression of high-energy grease fires
- Demonstrates cooling and re-ignition prevention
- Reflects real commercial cooking conditions
UL 300
EN 17446:2021 + A1:2024
Manufacturer-reported EN 17446:2021 + A1:2024 certification applies within its approved scope and relevant instructions.
LPCB LPS 1223 (Issue 2.3)
- UK certification for fixed fire suppression systems in catering environments
- Supports insurer and specifier acceptance
DW172 coordination
Coordinate with kitchen ventilation and extraction requirements; DW172 is not an independent system certification.
Certification supports compliance — system design and detection capability determine real-world performance.

Kitchen suppression within a managed fire safety programme
The Fire Safety Order applies in England and Wales. Appropriate suppression can support the precautions identified by a suitable fire risk assessment, but no brand or product alone makes a business compliant. Maintenance, extraction cleaning, fire separation, alarms, escape provision and staff training remain part of the wider strategy.
Appoint Equipro to project manage an agreed fire safety programme: assessments and actions, specialist systems, inspections, servicing, contractors, records and business continuity planning. The client retains its statutory responsibilities; our role, authority and deliverables are agreed clearly.
- Managing high-risk ignition sources
- Controlling rapid fire escalation
- Preventing fire spread beyond origin
- Protecting occupants, including vulnerable persons
Before you specify ANSUL, compare Amerex
Compare the actual coverage, cylinders, stored agent, detection, controls, installation and servicing. Amerex can use fewer agent cylinders or less stored agent in suitable layouts. We show the project-specific design calculation rather than promise a universal saving. Both brands offer appliance-specific and overlapping protection; the proposed configuration and its maintenance requirements deserve close examination.
Fire Risk Assessments
Comprehensive evaluation of kitchen hazards and occupancy risks.
Fire Door Strategies
Compartmentation strategies and compliance for high-occupancy sites.
Extinguisher Provision
LPCB certified portable fire extinguishers for manual intervention.
TR19 Duct Cleaning
Specialist ventilation hygiene and grease removal for fire prevention.
Emergency Lighting
Continuous testing and provision of reliable evacuation lighting.
Staff Training
Practical fire safety education and legal compliance support.
Fire suppression is one component of a complete fire safety strategy.
Proven Performance in High-Risk Environments
Equipro delivers Amerex KP systems to commercial kitchens with project-specific designs and maintenance requirements agreed for the premises.
HOSPITALITY
Prestige Central London Hotel
Fire suppression systems were designed for a recognised hospitality environment, integrating appliance, canopy and extract protection with the project requirements and maintenance arrangements.
Landmark UK hospitality environment standard.
MULTI-SITE QSR
Nationwide Restaurant Group
Standardised fire protection was deployed across multiple high-throughput kitchen environments, with project-specific design and servicing requirements agreed across the portfolio.
Scalable rollout across multi-location operations.
PUBLIC SECTOR
Critical Infrastructure Kitchens
Systems were implemented in environments requiring enhanced duty of care, with the approved design and maintenance arrangements documented for the premises.
Risk-managed fire safety in regulated environments.
Equipro systems are deployed across high-profile hospitality, multi-site restaurant, and critical infrastructure environments throughout the UK.