top of page

EQUIPRO • UK MASTER DISTRIBUTOR

Amerex kitchen fire suppression

Protect your kitchen. Keep your business running.

Amerex KP and STRIKE systems, backed by specialist design, installation, servicing and ongoing fire safety management. We explain the system, how its readiness can be checked and what is needed to keep it suitable as your kitchen changes.

AMEREX KITCHEN FIRE PROTECTION SYSTEMS By EQUIPRO LTD.mp4
00:00/00:00

Why Commercial Kitchens Require Engineered Fire Protection

High-energy Class F fires escalate rapidly in modern cooking appliances

Grease-laden ductwork presents hidden fire propagation risk

Unattended cooking equipment increases ignition probability

Fire events often lead to business interruption and insurance exposure

Commercial kitchens require an engineered combination of appliance, canopy and duct coverage, suitable detection and release, and a maintained system that matches the approved design.

FIRE SAFETY LAW • ARTICLE 17

A system that looks ready must also be able to work.

The Regulatory Reform (Fire Safety) Order 2005 is the fire safety law for workplaces and most non-domestic premises in England and Wales. It requires those responsible to assess fire risks and protect people.

Article 17: keep protection working

Where needed to protect people, fire precautions must have suitable maintenance and remain in efficient working order and good repair. A suppression system unable to discharge leaves a serious gap.

ANSUL R-102: a missing cartridge can go unnoticed

A conventional ANSUL R-102 system needs a separate gas cartridge to push the extinguishing liquid out of its tank. The release mechanism can look ready even when that cartridge is missing or has lost pressure. The system may therefore look ready but be unable to discharge properly onto a fire. The cartridge must be checked separately.

Amerex KP: pressure gauges you can check

Amerex KP stores its extinguishing liquid under pressure. A gauge lets you check that pressure. On the Amerex MRM and PRM versions, a second gauge shows the gas pressure used to activate the system. These checks help identify pressure loss between service visits. They support servicing; they do not replace it.

Why this matters: Article 17 requires necessary fire protection to be kept working. A ready indication alone is not proof that a system can discharge. Both systems need the manufacturer’s prescribed checks and maintenance.

Three questions every kitchen team should ask

Will it release the extinguishing liquid?

Check the extinguishing liquid and the gas pressure needed to operate the system. Follow the manufacturer’s instructions.

Who is checking it?

Agree who carries out routine checks. Use competent servicing, fix faults and record that the system has been returned to service after work.

Does your adviser understand fire safety law?

Kitchen designers, ventilation companies and installers need relevant fire safety training. Their trade experience alone does not show they understand Article 17.

Three ways to detect a kitchen fire

Amerex KP systems can sense a fire in three different ways. The right choice depends on your kitchen, its risks and how it is used.

Mechanical detection (MRM)

Heat-sensitive metal links operate a cable release when their rated temperature is reached. The arrangement needs regular inspection, testing and link replacement.

Pneumatic detection (PRM)

Heat-sensitive tubing runs through the protected area. A loss of pressure activates the release mechanism. The tubing needs inspection and replacement at the prescribed intervals.

Electronic detection (STRIKE)

Monitors the connected detection and release circuits, indicates faults and records events. The core control unit uses batteries. Connected equipment may need a separate power supply.

Every option needs an approved design, regular maintenance and functional testing.

KPHero2.jpg

What we check in your kitchen protection specification

Automatic and manual fire suppression activation

Suitable detection and manual release arrangement

Wet chemical agent delivery to high-risk areas

Permitted piping and nozzle arrangement

Approved appliance, canopy and duct coverage

Agreed fuel and electrical shutdown, alarm and ventilation interfaces

Standards that support your specification

We check the certification and installation requirements for the proposed system. An approval applies only within its stated scope.

EN 17446

European standard for commercial kitchen fire suppression systems. Amerex reports certification; we check the approved scope for your proposed installation.

LPCB LPS 1223

UK approval scheme for catering fire suppression systems. We verify the applicable product listing and installation requirements for the system specified.

DW172

Kitchen ventilation guidance. We coordinate suppression with the extraction design, canopy layout and shutdown arrangements.

UL 300 provides additional fire-test evidence. It does not establish compliance with UK fire safety law.

FIRE SAFETY MANAGEMENT FOR FOOD SERVICE & HOSPITALITY

One fire safety programme for your whole operation

Restaurants, hotels, pubs and catering businesses need more than a kitchen suppression system. Equipro can coordinate your fire safety work, keep inspections and servicing on track, and help you act on the gaps before they disrupt your business.

â–³

Protect the kitchen

Design, supply, install and maintain suppression. Review protection when appliances or cooking layouts change.

â–¡

Look after the premises

Coordinate fire risk assessments, alarms, emergency lighting, fire doors, extinguishers and extraction cleaning.

â—‹

Keep checks and records in order

Schedule periodic inspections and servicing, track corrective work and keep fire safety records up to date.

â—‡

Support your people and business

Arrange staff training, agree fault reporting and support business continuity and insurer requirements.

Licensing and fire authority support

For licensed venues, we help you demonstrate how fire safety supports the public safety licensing objective. If the fire and rescue service issues an enforcement or prohibition notice, we can coordinate an action plan, remedial works and evidence of compliance, and support discussions with the authorities. Prompt, effective action can help reduce disruption and the risk of a premises licence review, suspension or revocation. Restrictions in any prohibition notice must be observed.

Ongoing management on an agreed monthly basis, across one site or several. We agree the services, responsibilities and response arrangements with you. Your statutory duties remain with you.

Before you specify ANSUL, compare Amerex

Compare the actual coverage, cylinders, stored agent, detection, controls, installation and servicing. Amerex can use fewer agent cylinders or less stored agent in suitable layouts. We show the project-specific design calculation rather than promise a universal saving. Both brands offer appliance-specific and overlapping protection; the proposed configuration and its maintenance requirements deserve close examination.

Fire suppression is one component of a complete fire safety strategy.

Fire Risk Assessments

Comprehensive evaluation of kitchen hazards and occupancy risks.

TR19 Duct Cleaning

Specialist ventilation hygiene and grease removal for fire prevention.

Fire Door Strategies

Compartmentation strategies and compliance for high-occupancy sites.

Emergency Lighting

Continuous testing and provision of reliable evacuation lighting.

Extinguisher Provision

LPCB certified portable fire extinguishers for manual intervention.

Staff Training

Practical fire safety education and legal compliance support.

Proven Performance in High-Risk Environments

Equipro delivers Amerex KP systems to commercial kitchens with project-specific designs and maintenance requirements agreed for the premises.

HOSPITALITY

Prestige Central London Hotel

Fire suppression systems were designed for a recognised hospitality environment, integrating appliance, canopy and extract protection with the project requirements and maintenance arrangements.

Landmark UK hospitality environment standard.

MULTI-SITE QSR

Nationwide Restaurant Group

Standardised fire protection was deployed across multiple high-throughput kitchen environments, with project-specific design and servicing requirements agreed across the portfolio.

Scalable rollout across multi-location operations.

PUBLIC SECTOR

Critical Infrastructure Kitchens

Systems were implemented in environments requiring enhanced duty of care, with the approved design and maintenance arrangements documented for the premises.

Risk-managed fire safety in regulated environments.

Equipro systems are deployed across high-profile hospitality, multi-site restaurant, and critical infrastructure environments throughout the UK.

Speak to a Fire Protection Specialist

Get expert guidance on compliant, engineered kitchen fire protection systems.

Equipro Ltd — UK master distributor for Amerex kitchen fire suppression systems.

Prefer to email a brief? Use our contact form and a specialist will respond promptly.

bottom of page